TP-Lab multimeter Diagnosis 4.0 — Front panel with three program selector switches, indicator lights, relays, and MOSFETs, freestanding on a dark background
Generation 4.0 › Circuits & Diagnostics › TP-Lab multimeter Diagnostics 4.0
Generation 4.0 · Art. No. 12 020 240

Measure real faults.
And prove the diagnosis.

18 reproducible fault patterns in three circuits. The trainer doesn’t tell you what’s broken—it shows you the symptom. And Generation 4.0 completes the learning path: search, measure, repair, prove. Only when function is restored is the diagnosis confirmed.

18 Error Patterns · Levels 1 through 18
3 Circuit Types · Lamp · Relay · MOSFET
47 Measuring sockets · at each node
410min Exercisestime · plus E-Learning
Power Minute · 60 seconds

The trainer in one minute.

What the trainer does in class — shown in a minute, with sound. Subtitles can be switched on in the player.

Engineering Core

One fault per switch position. Reproducible.

Each of the three program selector switches introduces a defined fault into its section of the circuit—and then removes it again. No need to rewire, replace components, or make preparations between two groups. The teacher sets a number, and the class measures. Two minutes later, the next error pattern appears.

  • check_circle 3 program selector switches, each with seven positions — 18 faults plus "OK" status
  • check_circle 47 measuring sockets: each node in the circuit can be measured individually
  • check_circle Self-resetting fuse — Shuts off in case of measurement error; no components are damaged
  • check_circle 3 lamp circuits (10 W / 12 V) + 3 LEDs as indicator lights
  • check_circle Relay with separate control and load circuits, MOSFET stage with gate drive
TP-Lab multimeter Diagnosis 4.0 (Art. No. 12020240) front view against an orange background — three program selector switches, lamp circuits E1 through E3, relay K1, and MOSFET stage K2 Art. No. 12020240
What Makes This Trainer Special

Only the proof confirms the diagnosis.

It's not the stated fault. The 18 levels are designed so that the cause isn't determined until the end of the test series—and the trainee then corrects it on their own.

USP 01 · New in 4.0 build_circle

Fix
and prove it.

A diagnosis is only confirmed once functionality is restored. The self-resetting fuse allows the fault to be safely bypassed using a jumper wire—the student goes through the entire workshop workflow: search, measure, repair, prove. That’s the difference from the previous model.

USP 02 timeline

From the silent failure
to a dead transistor.

The levels are divided into three stages: first, the lamp circuit with voltage drop and contact resistance; then, the relay with its control and working circuits; and finally, the MOSFET stage with gate drive and negative voltages. Each stage builds on the previous one.

USP 03 psychology

Hypothesis first.
Then measure.

The tasks require a reasoned guess before the first measurement. This reveals whether someone is searching systematically or guessing—top-down versus component-by-component—and why that makes a difference.

USP 04 restart_alt

Faults set
in two seconds.

A switch instead of a tool. The trainer is ready for use again between two groups with no setup time, and the same fault can be reproduced exactly for the test—identically for every trainee.

Technical Data

Everything in detail.

01

Error Simulation

program selector switch3 × · 7 positions each
On/Off Toggle Switch3 ×
Error Patterns18 · Levels 1 through 18
Hedgingself-resetting
02

Load & Switchgear

Automotive Light Sockets3 × · 10 W / 12 V
LED3 ×
Relay K1Control + Load Circuit
MOSFET Stage K2Gate · Drain · Source
03

Electrical Specifications

power supply10–15V DC / 1–3 A
Recommended power supplyTS15 · 12.5 V DC / 16 A
Sound pressure level< 70dB(A)
04

Mechanics & Scope of Delivery

measuring sockets47 × · plus 4 × supply
Dimensions W × D × H266 × 297 × 110mm
Weight, approx.1.5kg
form factorTable · DIN-A4 Support Frame
Conformity
In the learning path · Circuits & Diagnostics

Where this trainer is located in the path.

The Multimeter Diagnosis 4.0 comes in once the circuits are solid and the focus shifts to finding faults. It builds on the fundamentals of the vehicle electrical system and progresses to signal diagnosis using an oscilloscope.

Curriculum

Three thematic sections, eighteen levels.

The tasks are not sorted but are arranged in stages: V1 performs voltage drop testing in the lamp circuit; V2 isolates the control and load circuits at the relay; V3 deals with the semiconductor drive. Includes a digital curriculum and accompanying E-Learning.

  • check_circle V1 · Voltage drop across the lamp circuit (Levels 1–6)
  • check_circle V2 · Relay: Control circuit vs. load circuit (Levels 7–12)
  • check_circle V3 · MOSFET Control, Gate, and Current Channel (Levels 13–18)
  • check_circle Hypothesis-Driven Diagnosis Instead of a Guessing Process
  • check_circle A Direct Comparison of Top-Down vs. Component-by-Component
  • check_circle Contact resistance and corrosion as the most common errors in practice
  • check_circle Evaluation Forms — It's the Process That Counts, Not Just the Result
  • check_circle Reproducible fault setups for the exam
TP-Lab Multimeter Diagnosis 4.0 — der Kurs auf TPGO, hier eine Aufgabe auf dem Tablet Derselbe Kurs auf dem Smartphone
E-Learning · TPGO

The course for the trainer.
On every screen.

The TP-Lab Multimeter Diagnosis 4.0 comes with a complete course on TPGO. It runs in the browser — tablet, phone, computer. The tasks walk through the same measurements the apprentice takes on the trainer: first the assumption, then the series of readings, then the comparison.

18
Tasks · with measurement series and evaluation
27
Chapters · from the basics to diagnostics
8 hrs
Hands-on · total task time
6
Languages · same task, different language

Fundamentals 17 % · Advanced 83 % SOLO 2–4 · Bloom's Taxonomy · EQF 2–3

  • DE KMK · LF03
  • NL MBO · 27113:B1-K1
  • UK IMI · MR02
  • US ASE · VI-A
  • FR Bac Pro · C1.2
  • CH BiVo · 5.5
  • ES CFGM · 0456
  • AU AUR · AURETR112

Examples — in total the course is mapped to more than 90 curricula.

Certificate · Progress & XP

License for an unlimited number of students and teachers · Term: 10 years, renewable · Activation on your TPGO E-Learning domain.

Request now arrow_forward
TP-Lab Multimeter Diagnosis, Art.-Nr. 12 020 210 — das Gerät der Vorgängergeneration

For existing customers

Your existing trainers get their course free of charge.

Buy one trainer from Generation 4.0 and the e-learning courses for every predecessor model you already own are unlocked with it. At no extra cost. For the TP-Lab Multimeter Diagnosis (Art. No. 12 020 210) that means 18 tasks in 27 chapters, around 8 hours of hands-on work — on the same domain, with the same progress.

The course covers the same material as its predecessor—with one exception: troubleshooting. Trainees not only find the fault, but also fix it. That is the pedagogical leap.

Tell us your inventory and have it unlocked arrow_forward
TP-Lab multimeter Diagnose 4.0 for Your Workshop

We'll bring it to you.

A demonstration lasts about two hours. We'll set up a fault and let you troubleshoot it—using your own multimeter. Afterward, you'll know if the trainer is a good fit for your class.

To take away

The flyer as a PDF.

Specifications, benefits, technical data and the task list — two pages, exactly as printed.

Download product flyerdownload
Exklusiv vorab

Als Erste/r informiert über TPGO

Melden Sie sich jetzt exklusiv an: Wir schicken Ihnen Neuigkeiten, Termine und Unterlagen zu TPGO, unserer Lernplattform für die Kfz-Ausbildung — ohne großes Formular.

Datenschutzerklärung